1. Das Sauerstoffanalysatorgerät PENY X2O kann mit zwei unabhängigen Infrarot-Detektionskanälen konfiguriert werden, um hohe bzw. niedrige Sauerstoffkonzentrationen zu erfassen.
2. Der Impulsofen verwendet eine Wasserkühlung und die Probe kann im Graphittiegel des Hochleistungs-Impulsofens auf eine hohe Temperatur von 3500 ℃ erhitzt werden, um eine vollständige Verbrennung zu gewährleisten und die Genauigkeit der Messung zu verbessern.
Product Introduction

A slightly higher oxygen level in metals, alloys, powders, or advanced materials can cause porosity, cracks, poor weldability, reduced fatigue life, and unstable electrical or thermal performance. Too often, it is found only after the batch has failed downstream processing or customer inspection — when the cost is already scrap, rework, delayed delivery, and damaged customer confidence.
Waiting 3–7 days for third-party testing delays incoming material approval and stalls production. Without fast, reliable oxygen determination, teams rely on supplier certificates, delayed testing, or guesswork — risking both accepted bad material and rejected good material.
Our Solution
The PENY X2O Oxygen Elemental Analyzer delivers fast, stable, and traceable oxygen results on solid samples from ppm to percentage levels. Based on inert gas fusion, it supports methods such as ASTM E1019 for steel, iron, nickel, and cobalt alloys, and ISO 4491 for metallic powders.
Typical analysis time: 2–3 minutes
Analysis range: 0.05 ppm – 20%
Detection limit: < 0.05 ppm
Repeatability: RSD < 1.5% (content > 50 ppm)
Sample weight: 0.03 g – 1.5 g
Key features: pulse furnace with water-cooled transformer · high-purity argon carrier gas system · imported gas-path components · automatic loading, degassing, release, calibration, integration, and blank subtraction · LIMS-compatible data export
What this means for your team: verify incoming material in 2–3 minutes instead of waiting 3–7 days · monitor process stability · release qualified batches faster · support supplier audits with traceable data · reduce dependence on external labs
Want to see how the X2O performs on your material? Send us a sample for testing.
Technical Specifications
| Parameter | Specification |
|---|---|
| Analysis range | Low: 0.05 ppm – 0.5% |
| High: 0.5% – 20.0% | |
| Analysis time | Typically 2-3 minutes, depending on sample type, weight, flux, and furnace program |
| Pulse furnace | Water-cooled transformer |
| Current | 0 – 1500 A |
| Furnace head | Automatic cleaning function |
| Power | 10 kVA |
| Maximum temperature | Up to 3500°C (nominal) |
| Heating program | Programmable heating function |
| Gas path system | Cylinders, gas path joints, air pipes, and solenoid valves use imported components |
| Carrier gas | High-purity argon gas, 99.999%, 0.3 – 0.5 MPa |
| Power gas | Ordinary nitrogen gas or purified compressed air, 0.3 – 0.5 MPa |
| Host machine power supply | AC 200/220/230/240 V ± 10%, 50/60 Hz ± 1 Hz |
| Dimensions | 850 × 700 × 655 mm (W × D × H) |
| Weight | 160 kg |
| Packaging | Fumigation-free wooden box |
Note: Actual analysis time and performance depend on sample preparation, flux selection, crucible condition, gas purity, and calibration. We recommend sample testing before final configuration.
Instrument Features
Vertical touch screen software: Single vertical screen display or dual-screen display is optional.
Automatic cleaning option: Built-in automatic cleaning system available. Software controls automatic furnace head cleaning and automatic negative-pressure dust collection.
Independently developed software: The operating software is developed by PENY. Communication protocols can be customized according to user requirements.
Data traceability: Analysis results, calibration data, and blank values are recorded for review and export.
Standard Configuration
Host machine
Operating software
Computer
Electronic balance
Dust collection device
Optional Configuration
Regulated power supply
Water cooler
Additional options such as custom communication protocols, spare parts kits, and extended service packages are available on request.
Installation Requirements
To ensure stable performance, please prepare the following before installation:
Power supply: AC 200/220/230/240 V ± 10%, 50/60 Hz ± 1 Hz
Carrier gas: High-purity argon, 99.999%, 0.3 – 0.5 MPa
Power gas: Ordinary nitrogen or purified compressed air, 0.3 – 0.5 MPa
Environment: Clean, ventilated, low-dust room with stable temperature and humidity
Cooling: Water cooler may be required depending on configuration and usage intensity
Space: Allow enough space for the host machine, computer, gas cylinders, and maintenance access
Workbench: Must support the weight of the host machine and accessories
Our team will provide a detailed pre-installation checklist after order confirmation.
Typical Applications
| Application | Typical Samples | Why It Matters |
|---|---|---|
| Steel, iron, and alloys | Steel, iron, nickel, cobalt alloys | Oxygen affects cleanliness, inclusions, mechanical properties, and weldability |
| Metallic powders and powder metallurgy | Iron powder, copper powder, alloy powder, sintered parts | Oxygen affects sintering, flowability, density, and porosity |
| Bearing, automotive, aerospace, and welding | Bearing steel, critical components, filler metals, welding wire | Oxygen deviation can reduce fatigue life, cause weld defects, and increase failure risk |
Note: Best suited for solid inorganic samples. Not for organic materials, liquids, or volatile samples. Sample testing recommended before configuration.
About Peny
PENY is a professional elemental analyzer manufacturer in China with 12 years of experience. Our factory is located in Nantong City, Jiangsu Province, with more than 2,000 m² of production space. Our research team consists of experienced technical personnel who have worked in this industry for over 10 years. We currently offer more than 15 types of analyzers for different customer requirements.
Our factory can produce 20–30 units per month. Standard analyzer delivery is approximately 30 days after order confirmation. For special configurations, please allow an additional 5–7 days. Each instrument is checked and calibrated before shipment.
We have obtained ISO 9001 certification and registered our trademark. We are also applying for high-tech enterprise recognition.


ISO 9001 certificate

Quality Control
Jeder PENY X2O Sauerstoff-Elementaranalysator wird unter einem dokumentierten Qualitätskontrollsystem hergestellt.
Wareneingangsprüfung — Wichtige Komponenten wie der Impulsofen, Gaswegkomponenten, Magnetventile und elektronische Module werden vor der Produktion anhand der Eingangsqualitätsstandards geprüft.
Montagekontrolle — Gasweg, Ofenkopf und elektrische Verkabelung werden in jeder Phase überprüft, um Leckagen, Signalabweichungen und Verbindungsfehler zu vermeiden.
Kalibrierung und Werksprüfung Jedes Gerät wird vor dem Versand kalibriert und mit Standardproben geprüft. Die Leistungsfähigkeit wird gemäß ASTM E1019 für Stahl-, Eisen-, Nickel- und Kobaltlegierungen sowie gemäß ISO 4491 für Metallpulver hinsichtlich Nachweisgrenze, Wiederholbarkeit und Analysebereich verifiziert. Geräte, die die Werksabnahme nicht bestehen, werden nicht zum Versand freigegeben.
Rückverfolgbarkeit — Jedes Instrument verfügt über ein Produktions- und Prüfprotokoll. Kalibrierungsdaten und Testergebnisse werden zur Qualitätsrückverfolgbarkeit archiviert.
Verpackung — Begasungsfreie Holzkiste mit Schutzmaßnahmen für die Hauptmaschine, Zubehör und Gaswegkomponenten.
PENY hat die ISO 9001-Zertifizierung erhalten. Inspektions- und Kalibrierungsberichte können eingesehen werden.
Kundenfall

ZhenTe New Material Technology Co.,Ltd.
ZhenTe New Material Technology ist ein Hersteller, der neue Werkstoffe und Metallprodukte erforscht und entwickelt. Sie stellen sehr strenge Testanforderungen. Nach einem Besuch in unserem Werk,PgekauftDasKohlenstoff-Schwefel-Analysator und ONH-Analysator. Die Produktionseffizienz wird dadurch erheblich verbessert.

Wafangdianische Bärengruppe
Die Wafangdian Bearing Group wurde 1938 gegründet und produziert über 20.000 verschiedene Wälzlager mit unterschiedlichen Präzisionsstufen. Aufgrund des rasanten Wachstums musste die Wafangdian Bearing Group den Bedarf der heimischen High-End-Maschinenbauindustrie decken. Diese fand uns, besuchte unser Werk und erwarb nach mehreren Tests schließlich unseren Kohlenstoff-Schwefel-Analysator.
Garantie
| Artikel | Bedingungen |
|---|---|
| Garantiezeitraum | 12 Monate ab Installation oder 15 Monate ab Versand, je nachdem, welches Ereignis zuerst eintritt |
Häufig gestellte Fragen
F: Bieten Sie kostenlose Schulungen an?
A: Ja. Wir bieten nach der Installation eine kostenlose Kundenschulung an. Die Schulung kann per Video, Telefon oder bei Bedarf vor Ort erfolgen. Reise- und Übernachtungskosten für die Schulung vor Ort werden separat besprochen.
F: Wie oft sollten CO2-Absorptionsmittel und farbveränderndes Trockenmittel ausgetauscht werden?
A: Es gibt keinen festen Austauschzyklus. Dieser hängt von der Nutzungshäufigkeit und der Art des Produkts ab. Bei Verfärbungen oder Leistungsveränderungen sollten die Produkte umgehend ausgetauscht werden.
F: Wie lange ist die Lieferzeit?
A: Die Standardlieferzeit beträgt ca. 30 Tage nach Auftragsbestätigung. Sonderanfertigungen können 5–7 zusätzliche Tage in Anspruch nehmen. Wir bestätigen Ihnen den genauen Liefertermin vor Ihrer Bestellung.
F: Können Sie unsere Muster vor dem Kauf testen?
A: Ja. Wir empfehlen, vor der Konfiguration Mustertests durchzuführen. Bitte kontaktieren Sie unser Vertriebsteam bezüglich des Verfahrens zur Mustereinreichung und der Testdauer.
F: Welche Informationen benötigen wir für ein Angebot?
A: Bitte geben Sie Ihre Probenart, den erwarteten Sauerstoffbereich, die Probengröße, die Testhäufigkeit, die Spannungsanforderung und alle speziellen Software- oder Kommunikationsanforderungen an.
F: Was ist die Mindestbestellmenge?
A: 1 Einheit.
F: Wie wird das Analysegerät versendet?
A: Versand per Seefracht. Verpackung: begasungsfreie Holzkiste.